• Industrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water Chiller
  • Industrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water Chiller
  • Industrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water Chiller
  • Industrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water Chiller
  • Industrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water Chiller
  • Industrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water Chiller

Industrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water Chiller

After-sales Service: 1 Year
Warranty: 1 Year
Type: Air-Cooled
Cooling Method: Air-cooled
Unit Structure: Integral
Selected Voltage: 380V/50HZ
Customization:
Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
L5W/L8W/L10W/L12W/L15W/L20W/L25W/L30W/L40W/L50W
Compressor Number
1
Noise Level
Ultra Quiet
Application Fields
Plastic
Application Machine
Combination machine
Condition
New
Compressor
Japan Panasonic
Imported Refrigeration Parts
Emerson
Electrical Parts
German Siemens
Transport Package
Wooden Case
Trademark
BEIERMAN
Origin
Zhangjiagang, China
HS Code
847780000
Production Capacity
20000pieces/Year

Product Description

Product Pictures
Industrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water Chiller
Industrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water Chiller
Industrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water Chiller
Industrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water Chiller
Industrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water Chiller
Product Description

Model Features
1.No need to fit the cooling tower.
2.Japan Panasonic compressor, high efficiency, low noise, quiet operation.
3.Emerson imported refrigeration parts.
4.Electrical parts are German SIEMENS genuine, to ensure stable operation of the machine.
5.Take a large capacity condenser and heat it can run easily.
6.Minimize floor space and ease of installation.
7.All pipe insulation design, to prevent local convection of the pipeline.
8.Finned condenser, better heat transfer, faster heat dissipation.
9.Box type evaporator is provided with an automatic water replenishing device.
10.Our company is based on high product quality, and developing on in-novative technology.
Pay attention to the development of new productsand new technologies. Continue to enhance the quality of products,reduce costs to meet the needs of the market.


Safety System
1.Compressor Overload Protection
2.Pump Overload Protection
3.Heat-Exchange Fail Protection
4.Refrigerant Safety Valve
5.Freeze Protection
6.High Pressure Protection
7.Low Pressure Protection
8.Phase Failure Protection
9.Buzzer


Technical Data
Model LF5AH LF8AH LF10AH LF12AH LF15AH LF20AH LF25AH LF30AH LF40AH LF50AH
Cooling
Capacity
kw/h 50Hz
60Hz
13
16
21
25
26
31
30
36
42
50
55
66
60
71
84
100
111
133
119
143
kcal/h 50Hz
60Hz
11180
13760
18060
21500
22360
26660
25800
30960
36120
43000
47300
56760
51600
61060
72240
8600o
95460
114380
102340
122980
Input Power kw 6   10 12 16 20 23 33 41 48
Voltage 3PH-38OV-5OHz(Or 200V/220V/415V50Hz/60Hz)
Refrigerant Name R22(Or R134a/R407c)
Control Method Outside The Balanced Thermal Expansion Valve
Compressor Types Fully Enclosed Scroll Compressor
(kw)
Power
3.73 5.97 7.46 8.95 11.19 14.92 18.64 22.38 29.84 37.28
Evaporator Types Tank Coil
(m/h)
Chilled Water
2.24
2.68
3.52
4.22
4.47
5.37
5.12
6.15
7.20
8.63
9.52
1142
10.25
12.29
14.39
17.37
19.05
29.86
20.50
24.60
(L)
Water Tank
50 120 120 120 200 250 330 450 600 720
Water Pipe 1 1-1/2 1-1/2 1-1/2 1-1/2 2 2 2 3 3
Condenser Types Efficient Aluminum Finned Copper Jacket+Low Noise External Rotor Fan
(m/h)
AirCooling
5000 8000 10000 12000 15000 20000 25000 30000 40000 50000
Pump (kw)
Power
0.37 0.75 0.75 0.75 1.5 2.25 2.25 2.25 4 5.5
H(m) 20 22 22 22 24 30 30 30 40 52
Heating
equipment
Types Heating pipe
(kw)Power 6 9 12 18 24 30 40 60 90 120

Dimensions
 
L(mm) 1360 1600 1570 1570 1910 2230 2230 2350 3070 3070
w (mm) 645 860 860 860 88o 1100 1100 1170 1200 1200
H(mm) 1130 1555 1580 1580 1560 1680 1680 1980 2040 2040
Weight kg 300 400 450 450 600 880 980 1100 1250 1400
Unit Conversion 1KW=860KCAL/HR 1RT=3024KCAL/HR 1BTU/HR=0.252KCAL/HR
Industrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water ChillerIndustrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water ChillerIndustrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water ChillerIndustrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water ChillerIndustrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water ChillerIndustrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water ChillerIndustrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water ChillerIndustrial Air Conditioning Air Source Heat Pump Air Cooled Industrial Water Chiller

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2023

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
26
Year of Establishment
2017-11-18